cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Jurnal Radioisotop dan Radiofarmaka
ISSN : -     EISSN : -     DOI : -
Core Subject : Health,
Jurnal Radioisotop dan Radiofarmaka (Journal of Radioisotopes and Radiopharmaceuticals) bertujuan untuk memajukan ilmu pengetahuan dan teknologi di bidang radioisotop, radiofarmaka dan bidang terkait, yang diwujudkan dalam bentuk makalah ilmiah hasil penelitian atau tinjauan dan gagasan.
Arjuna Subject : -
Articles 5 Documents
Search results for , issue " Vol 15, No 2 (2012): JURNAL PRR 2012" : 5 Documents clear
EVALUASI PENGELASAN LASER PADAPEMBUATAN MIKROKAPSUL BRAKHITERAPI LAJU DOSIS RENDAH Yoga, Diandono Kuntjoro; Pujiyanto,, Anung; Subechi,, Mochamad; Awaludin, Rohadi
Jurnal Radioisotop dan Radiofarmaka Vol 15, No 2 (2012): JURNAL PRR 2012
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAKEVALUASI PENGELASAN LASER PADA PEMBUATAN MIKROKAPSULBRAKllITERAPI LAJU DOSIS RENDAH.Pembuatan mikrokapsul brakhiterapi laju dosis rendahmemerlukan proses yang cukup rumit sehingga perlu dilakukan evaluasi pada setiap tahap pembuatannya.Ukuran mikrokapsul yang sangat kecil dan penggunaan las laser yang memiliki banyak parameter menuntutevaluasi agar mendapatkan teknik pengelasan yang lebih efisien dan produk yang aman ketika diimplan kedalam tubuh pasien. Penelitian ini mengevaluasi penggunaan energi laser, gerakan pengelasan dankemungkinan perubahan komposisi unsur material setelah proses pengelasan. Evaluasi energi laserdilakukan dengan membandingkan pilihan bentuk pulsanya terhadap tembusan pengelasan. Gerakanpengelasan dibandingkan antara memutar pada sumbu vertikal terhadap gerakan memutar menggunakansumbu x dan y. Sedangkan unsur material diamati menggunakan scanning electron microscopy (SEM).Penggunaan bentuk pulsa spike with ramp down dapat menurunkan penggunaanjUll power hingga 40% danhasil pengelasan pada daerah pelelehan terjadi peningkatan persentase C dan 0 namun tidak ditemukanpenambahan unsur Ar dari gas selubung sehingga cukup aman untuk diimplan ke dalam tubuh pasien.Kata kunci: mikrokapsul, brakhiterapi, las laserABTRACTEVALUATION OF LASER WELDING PROCESS IN LOW DOSE RATEBRACHYTHERAPY MICROCAPSULES PRODUCTION.Preparation of low dose rate brachytherapymicrocapsules requires a complicated process that needs to be evaluated at each step of manufacture.Microcapsule size is very small and the use of laser welding has many parameters that should be evaluated inorder to obtain an efficient welding technique and to get safe products that can be implanted into the bodytissues. This study evaluated the use of laser energy, the movement of welding process and possible changesin the elemental composition of the material after the welding process. Evaluation was carried out bycomparing the energy of laser pulse shape option to welding penetration. Welding movement was comparedbetween turning on the vertical axis of the circular motion using x and y axes. The elements of the materialwere observed using scanning electron microscopy (SEM). The use of spike pulse shape with ramp down canreduce power usage up to 40%, the increase in the percentage of C and 0 in melting regions was found,additional elements of argon was not found, and hence microcapsule was safe to be implanted into the bodytissues.Key-words: microcapsule, brachytherapy, laser welding47
EVALUASI PEMBUATAN l31I-MIBG RADIOFARMAKA DIAGNOSA DAN TERAPI NEUROBLASTOMA Astuti, Laksmi Andri; Purwoko, Purwoko; Setyowati, Sri; Maskur, Maskur; Ardianto, Cahya Nova; Gunawan, Adang Hardi
Jurnal Radioisotop dan Radiofarmaka Vol 15, No 2 (2012): JURNAL PRR 2012
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAKEVALUASI PEMBUATAN 13tI-MIBG SEBAGAI RADIOFARMAKA DIAGNOSA DANTERAPI NEUROBLASTOMA.Telah dilakukan evaluasi pembuatan 1311-MIBGsebagai radiofarmakadiagnosa dan terapi neuroblastoma. Preparasi 13t1_MIBGdilakukan dengan cara menandai MIBG hasilsintesa dengan radionuklida 1311,hasil penandaan dianalisis dengan kromatografi lapis tipislkromatografikertas untuk mengetahui kemumian radiokimianya. Uji stabilitas 1311-MIBGmeliputi uji stabilitas sediaanpada plasma darah manusia, pada suhu kamar, serta pada suhu pendingin (8°C). Hasil sintesis MffiG yangtelah dilakukan sebelumnya menunjukkan kemumian kimia > 95 %, penandaan MIBG dengan 1-131 telahdilakukan dengan kemumian radiokimia > 95%. Hasil pengamatan uji stabilitas 1311_MffiGpOOasuhukamar menunjukkan bahwa sediaan stabil pada suhu kamar sampai 120 jam. Pada plasma darah manusiastabil sampai 141jam, sedangkan pada suhu pendingin kulkas (8°C) sediaan stabil141 jam. Hasil penandaandari tahun 2011-2012 menunjukkan bahwa sediaan radiofarmaka 1311MIBG berupa larutan jemih takberwarna, pH antara 5,5-7,0, steril dan bebas pirogen, kemumian radiokimia > 95 %, dan memenuhipersyaratan sebagai sediaan injeksi untuk digunakan dalam diagnosa maupun terapi neuroblastoma di rumahsakif.Kata kunci : radiofarmaka, 1-131,MIBG, neuroblastomaABSTRACTEVALUATION FOR PREPARATION OF 131I_MIBG FOR NEUROBLASTOMADIAGNOSIS AND THERAPY.Evaluation for preparation of l311-MIBG has been carried out.Production/preparation of 1311-MIBGwas carried out by labeling MIBG with 1-131.The radiochemical purityof 1311-MIBGwas analysed using TLC/paper chromatography. The stability testing in the fresh humanplasma, at room temperature and at 8°C was carried out . The chemical purity of synthesized MIBG wasfound to be > 95%. The radiochemical purity of l311-MIBGwas obtained at higher than 95 %. The labeledMIBG in fresh human plasma and at 8°C was stable up to 141 hours, while at room temperature was stableup to 120 hours.The results of labeling of l311-MlBG from 2011-2012 showed that these products werecolorless clear solution with pH between 5.5 -7.0, sterile and pyrogen-free, radiochemical purity> 95%. Thequality control results be met the requirements of l311-MlBG injection solution used for diagnosis andtherapy of neuroblastoma in hospital.Key-words: radiopharmaceutical, MIBG, 1-131,neuroblastoma57
PREPARASI KIT CAIR TETROFOSMIN UNTUK DETEKSI KANKER DAN PERFUSI JANTUNG Widyastuti, Widyastuti; Setyowati, Sri; Rustendi, Cecep Taufik; Yunilda, Yunilda
Jurnal Radioisotop dan Radiofarmaka Vol 15, No 2 (2012): JURNAL PRR 2012
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAKPREPARASI KIT CAIR TETROFOSMIN UNTUK DETEKSI KANKER DAN PERFUSI JANTUNG.Kit tetrofosmin yang ditandai dengan teknesium-99m telah digunakan secara luas di bidang kedokteran nuklir untuk deteksi perfusi jantung dan deteksi kanker, yang dikenal dengan nama Myoview. Telah dilakukan pembuatan kit cair tetrofosmin untuk ditandai dengan teknesium-99m sebagaistudi awal dalam pengembangan radiofarmaka 99mTc-tetrofosmin untuk mempelajari teknik pembuatan,pengujian dan kestabilannya dalam penyimpanan. Metode uji kemumian radiokimia menggunakankromatografi lapis tipis (KLT), kromatografi kertas (KK) dan pemisahan dengan kolom SepPak CI8 telah divalidasi menggunakan larutan perteknetat 99mTcdan 99mTc-tetrofosmin dari kit impor (Myoview) sebagaistandar. Karakterisasi tetrofosmin, 99mTcdan 99mTc-tetrofosmin menggunakan kromatografi cair kinerjatinggi (HPLC) telah dilakukan dan menunjukkan perbedaan waktu retensi yang cukup signifikan antara99mTc dan 99mTc-tetrofosminyaitu 6 dan 8 menit. Pengujian kemumian radiokimia terhadap 3 batch kit tetrofosmin yangdilakukan menggunakan KLT dengan fase diam ITLC-SG dan eluen campuran aseton dan diklorometan (35 : 65), KK denganfase diam kertas Whatman-3 dan eluen etil asetat serta kolom Sep Pak CI8 dengan eluen larutan NaCI fisiologis (salin) menunjukkan kemumian radiokimia rata-rata 85,89%(SD=I,44%) dan stabil pOOapenyimpananan di suhu -80°C hingga 2 bulan. Hasil penelitian menunjukkan bahwa kit tetrofosmin dalam bentuk cair telah berhasil dibuat dan dapat ditandai dengan 99mTc-dengan kemumian radiokimia yang cukup tinggi meskipun belum sesuai dengan persyaratan kit pada umumnya.Kata kunci : 99mTc-Tetrofosmin,kemumian radiokimia, diagnosis, perfusi jantung.ABSTRACTPREPARATION OF TETROFOSMIN FROZEN KIT FOR CANCER DETECTION ANDMYOCARDIAL PERFUSION.Tetrofosmin labeled with technetium-99m has been widely used in nuclear medicine as myocardial perfusion imaging agent and for use in cancer detection, with brand name of Myoview. Preparation of tetrofosmin liquid kits labeled with 99mTchas been carried out as a preliminary study in development of tetrofosmin radiopharmaceuticals which focuses in the techniques of preparation, quality control and stability study upon storage. Analytical methods using thin layer chromatography (TLC), paper chromatography (PC) and SepPak Cl8 have been validated using pertechnetate 99mTcand 99mTctetrofosmin from commercial product (Myoview) as standards. Characterisation of tetrofosmin, 99mTcclan99mTc-tetrofosminusing HPLC has also been carried out which showed significant difference in retention time between 99mTcand 99mTc-tetrofosmini.e 6 and 8 minute. Radiochemical purity testing in 3 batches of tetrofosmin kits uses TLC with ITLC-SG and mixture of acetone and dichloromethane (35:65), PC with Whatman-3 and ethyl acetate as eluants and SepPak Cl8 cartridge eluted with saline showed radiochemicalpurity of 85,89% (SD=I,44%) which was stabile up to 2 months upon storage in -80°C. Results showed thatwet preparation of tetrofosmin kits can be labeled with 99mTcwith high labeling efficiency although notsufficiently high as stated in the common requirements of radiopharmaceuticals.Key-words: 99mTc-tetrofosmin,radiochemical purity, diagnosis, myocardial perfusion
PREPARASI TARGET PADAT TELURIUM UNTUK PEMBUATAN RADIOISOTOP 123I Sarwono, Daya Agung; Amiruddin, Cahyana; Widyaningrum, Triani; Triyanto, Triyanto
Jurnal Radioisotop dan Radiofarmaka Vol 15, No 2 (2012): JURNAL PRR 2012
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAKPREPARASI TARGET PADAT TELURIUM UNTUK PEMBUATAN RADIOISOTOP 1231.Radioisotop lodium-123 (1231)da~at digunakan sebagai bahan sediaan radiofarmaka untuk pencitraan denganalat SPECT. Hal ini disebabkan 231 memancarkan sinar gamma dengan energi 159 keY dengan waktu paro(t1/2) 13,2 jam. Radioisotop 123 1 dapat dibuat dari bahan sasaran berupa lapisan tipis target padat telurium(Te), kemudian, diradiasi menggunakan siklotron. Salah satu teknologi untuk pembuatan lapisan tipis targetpadat Te adalah elektroplating. Untuk pembuatan lapisan tipis target padat telurium secara elekroplatingpada keping Cu diperlukan lapisan logam sebagai interface. Hal ini disebabkan logam telurium tidak dapatmenempel secara langsung pada keping Cu. Bahan yang dapat dipakai sebagai interface adalah logam nikelsebagai lapisan perekat antara keping Cu dengan target telurium. Tujuan dari kegiatan ini adalah untukmencari kondisi yang optimal elektroplating nikel dalam keping Cu dan elektroplating telurium dalamkeping Cu yang telah dilapisi nikel. Elektroplating nikel dilakukan pada variasi kuat arus dalam suasanaasam (pH 4) dan suasana basa (pH 10) sedangkan elektroplating telurium dilakukan dengan variasi kuat arusdalam suasana basa (pH 10). Dari hasil kegiatan diperoleh bahwa elektroplating nikel pada kuat arus 200 mAdalam suasana asam (pH 4) memberikan hasil yang optimal dengan efisiensi sebesar 88,86%. Elektroplatingtelurium pada kuat arus 100 mA pada suasana basa (pH 10) memberikan hasil yang optimal. Teluriummelekat kuat pada keping Cu yang telah dilapisi nikel dengan hasil yang halus dan rata serta efisiensiterbesar 56,97 %.Kata kunci : lodium-123, target padat telurium, elektroplating.ABSTRACTPREPARATION OF TELLURIUM SOLID TARGET FOR 1231 RADIOISOTOPEPRODUCTION. Radioisotope of iodine-123 (1231) can be used in a radiopharmaceutical preparation forSPECT imaging. 1231emits positron, gamma rays 159 keY with half-life 13.2 hour. Radioisotope 1231 can bemade by cyclotron irradiation from a thin layer of tellurium (Te) solid targets. One of the methods forpreparation of thin layers of solid targets Te is electroplating. A thin layer of solid material is required on theCu metal surface as an interface, since the tellurium can not be attached directly to the Cu. Materials that canbe used as an interface is nickel metal, as an adhesive layer between Cu and tellurium. The purpose of thisexperiments is to fmd the optimal conditions in the nickel electroplating on Cu and tellurium electroplatingon Cu surface coated with nickel. Nickel electroplating was performed in acid (pH 4) and alkaline (pH10) with electric current variation. Electroplating of tellurium was performed on current variation underalkaline (pH 10). The results showed that nickel with currents of 200 mA under acidic (pH 4) providedoptimal results with an efficiency of 88.86%. Tellurium electroplating with 100 mA of electric current inalkaline conditions (pH 10) provided optimal results. Tellurium is strongly attached to the Cu coated withnickel. The electroplated Te is smooth and flat with the greatest efficiency of 56.97%.Key-words: lodine-123, tellurium solid target, electroplating
PROSPEK PEMBUATAN RADIOLANTANIDA KERADIOAKTIV AN JENIS TINGGI BERBASIS REAKSI INTI AX (n;y) MiX· -+ A+ly· + ,,- DENGAN REAKTOR G.A. SIWABESSY Soenarjo, Sunarhadijoso
Jurnal Radioisotop dan Radiofarmaka Vol 15, No 2 (2012): JURNAL PRR 2012
Publisher : Jurnal Radioisotop dan Radiofarmaka

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAKPROSPEK PEMBUATAN RADIOLANTANIDA KERADIOAKTIV AN JENIS TINGGI BERBASIS REAKSI INTI AX (o;y) A+IX· •• A+ly· + ,r DENGAN REAKTOR G.A. SIWABESSYPenyediaan radiolantanida dengan keradioaktivan jenis tinggi merupakan kunci penting bagi pengembangan aplikasi radiofarmaka bertanda radiolantanida yang mulai banyak menjadi pilihan dalam penanganan berbagai kasus tumor. Di dalam Iingkungan domestik, dengan menggunakan reaktor G.A. Siwabessy yang dimiliki BATAN, reaksi inti AX (n,y) A+IX· •• A+ly· + ~- merupakan tipe reaksi inti yang paling mungkindilakukan untuk menghasilkan radiolantanida 143pr, 149pm, 161Tb, dan 177Lu keradioaktivan jenis tinggi, yang telah banyak digunakan dalam bentuk radiofamaka untuk penanganan  tumor kecil sampai sedang. Dalam makalah ini disajikan tinjauan prospek pembuatan radiolantanida keradioaktivanjenis tinggi yang disebutkan di atas di dalam lingkungan domestik dengan menggunakan reaktor G.A. Siwabessy. Tinjauan mencakup 3 aspek utama yaitu pemilihan bahan sasaran, karakteristika matrik radioisotop pasca iradiasi serta tahapan pemisahan produk akhir dari matrik bahan sasaran pasca iradiasi. Diharapkan hasil kajian ini dapatmemberikan dasar pertimbangan bagi pihak internal terkait di Iingkungan BATAN, khususnya PRR (Pusat Radioisotop dan Radiofarmaka) untuk mengambil kebijakan dan pilihan alternatif dalam pengembangan penelitian dan layanan penyediaan radiolantanida keradioaktivan jenis tinggi untuk dan dari lingkungan domestik.Kata kunci: Radiolantanida, keradioaktivanjenis tinggi, reaksi inti AX (n,y) A+IX· •• A+ly· + ~-,terapi dandiagnosis tumor, radioisotop bebas pengemban, radioisotop tanpa tambahan pengemban.ABSTRACTPROSPECT ON THE PREPARATION OF IDGH-SPECIFIC ACTIVITYRADIOLANTHANIDES BASED ON [AX (o,y) A+IX* •• A+ly* + IJ-]NUCLEAR REACTION BYMEANS OF BATANS G.A. SIWABESSY REACTOR.The preparation of high-specific activity radiolanthanide is an important key to improve the application of radiolanthanide-based-radiopharmaceuticaI which are nowadays growing fast to be used as tumor therapeutic agent. By using the BATAN - G.A.Siwabessy nuclear reactor the tipical nuclear reaction of AX (n,y) A+IX· -+ A+ly· + ~- is to be the most possible method to produce high-specific activity radiolanthanides of 143Pr, 149pm, 161Tb, and 177Lu, which are widely studied and used in the therapy of small to medium size of tumors. In the presented paper, the prospect on the production 0fhg1h -specifiICacti" vIty 143rp, 149mp , 161T,band I77Lu is revewed compnsing 3aspects, e.g. the choice of target compounds, the characters of radioisotope in the matrix of post-irradiated target, and the method for separation of the end-product from the post -irradi- ated  target matrix as well. This hopefully could be used as based consideration in order to improve research and development related to domestic services on the preparation of high-specific activity radiolanthanide.Key-words: Radiolanthanides, high-specific activity, nuclear reaction of AX (n,y) A+IX· -+ A+ly· + ~-,tumor therapy and diagnosis, carrier-free radioisotopes, non-carrier-added radioisotopes.90

Page 1 of 1 | Total Record : 5