Journal of Dentistry Indonesia
Vol 17, No 1 (2010): April

Evaluation in Accuracy to Two Impression Techniques: In Case of Bone Anchored Bridge

Sularsih, Sularsih ( Department of Dental Materials and Technology, Dentistry Faculty, Hang Tuah University )
Ishida, O. ( Department of Dental Laboratory and Technology, Tokushima University Hospital )
Ashrin, Meinar Nur ( Department of Dental Material and Technology, Dentistry Faculty, Hang Tuah University )
Okajima, M. ( Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, Tokushima University )
Ichikawa, T. ( Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, Tokushima University )



Article Info

Publish Date
23 Jul 2013

Abstract

Purpose: The purpose of this study was to investigate and compare the accuracy of two procedures: open tray with splinting technique and closed tray impression techniques, in innovative in vitro experiments. Materials and Methods: One master cast was fabricated with 4 abutment replica implants with almost parallel position in an anterior region of an edentuloys mandibular plaster cast. The working cast was taken impessions with open tray splinting technique (group 1) and closed tray technique (group 2) using polyvinyl siloxane impression material. The Type III dental stone ws poured into around the impressions. The accuracy of impression procedured were measured 24 hours long after pouring dental stone to each impression. Four sited were marked to measured on every platform of implant analogs. The analyzing stylus was positioned to each site and the heights, horizontal inclination and saggital incliniation were measured using the Laser displacement transducer (LK G115; Keyence, Osaka, Japan). Measurements of these 16 points of four implants per a model was repeated 7 times under the same condition. The gap between the abutment and superstructure at one screw test was evaluated with a digital microscope system (VH-Z100 & VH-5000; Keyence, Osaka, Japan). The mean and standard deviation estimated from the samples of each subgroup were statistically analyzed by ANOVA test (P<0.05 as the level of significance). Results: The relative differences of implant heights, horizontal inclination and saggital inclination of each implant on closed tray technique was statistically different to master cast and open tray with splinting (P<0.005). Conclusion: The open tray technique was more accurate comparing to the closed tray technique. The gap between the abutment and superstructure in the open tray with splinting technique was smaller comparing to closed tray technique.DOI: 10.14693/jdi.v17i1.111

Copyrights © 2010






Journal Info

Abbrev

JDI

Publisher

Subject

Dentistry Medicine & Pharmacology

Description

Journal of Dentistry Indonesia (JDI) is a scientific journal that is published three times annually (April, August and December). This journal aims for continuous dissemination of updates in relation to dentistry and its related fields in the form of original articles, case reports and reviews. Its ...