Lubis, Rakhmad Syafutra
Universitas Syiah Kuala

Published : 2 Documents
Articles

Found 2 Documents
Search

Disign SPWM multilevel inverter single phase15 level

Jurnal Rekayasa Elektrika Vol 12, No 2 (2016)
Publisher : Universitas Syiah Kuala

Show Abstract | Original Source | Check in Google Scholar | Full PDF (902.243 KB)

Abstract

Abstract — Fifteen level single phase multilevel inverter is constructed using power circuit consist of 7 MOSFETs as switch, 7 indevendent DC sources, 7 diodes, and a H-Bridge. Trigering technic using sinusoidal pulse width modulation (SPWM) with 14 carrier wave, which pure sinusoidal wave as reference, SPWM circuit is disained using Op-Amp as comparator and some logic gates such as AND, OR and NOT gate in order to triggering S1, S2, S3, S4, S5, S6 and S7. By modificated carrier wave from triangular into DC source wave, this MLI produces THD output wave equal to 5.5019684%, while using methodes Phase Disposition PWM (PD PWM), Phase Shift PWM (PS PWM), and Carrier Overlapping PWM (CO PWM) produces THD more than proposed method, this system simulated using PSIM program. Keywords: Multilevel Inverter, SPWM, THD, PSIM

Studi Kasus Kelayakan Penerapan Sistem Hybrid Building Applied Photovoltaics (BAPV)-PLN pada Atap Gedung Politeknik Aceh

Jurnal Rekayasa Elektrika Vol 13, No 1 (2017)
Publisher : Universitas Syiah Kuala

Show Abstract | Original Source | Check in Google Scholar | Full PDF (1063.012 KB)

Abstract

With the undeveloped BAPV(Building Applied Photovoltaics) at Office Building and Public Facilities, Caused the high price of solar modules and the lack the economic study on the use of solar modules that housed in the Banda Aceh region. Furthermore, the price of solar modules is expensive, so people think it will cost so much funds to building a BAPV’s system. These problems could be overcomed if the existing technical studies and economic studies of the application of the BAPV’s system. This study aims to assess the application of the BAPV’s system on institutions  building in terms of technical and economic value, in this case the building that is used as the study object is the Polytechnic Aceh’s Building. The method that used in the technical studies are theoretical calculations and simulations using helioscope software, while the methods used for economic studies is using the methods of cost-benefit analysis (cost benefit analysis). The method used to find the NPV (Net Present Value), PP (Payback Period), IRR (Internal Rate of Return), and BCR (Benefit Cost Ratio). If the average value of solar radiation reaching 4.79 kWh / m2 / day and the average daily energy requirement is 592 kWh, the energy generated from BAPV-PLN hybrid system on the roof of the object building will reach the amount of 237 MWh/year with the capacity charge controller used is 7490 A and the capacity of the battery used is 64.487 Ah. Panel tilt angle used is 25o and the type of panel used is Monocrystalline manifold. From the economic value will obtained NPV value of Rp. 20.022.106.937, PP during 5,2 years, IRR of 36% and 3,49 of BCR. Based on the evaluation results of the feasibility study, the project of hybrid BAPV-PLN’s system on the roof of the Polytechnic  Aceh’s  building can be realized, because its already meet the criteria of the feasibility study to make the systems get established in real term.