M. W. Mustafa, M. W.
Universiti Teknologi Malaysia

Published : 3 Documents
Articles

Found 3 Documents
Search

Algorithm for Fault Location and Classification on Parallel Transmission Line using Wavelet based on Clarke’s Transformation Saini, Makmur; Mohd Zin, A. A.; Mustafa, M. W.; Sultan, A. R.; Nur, Rusdi
International Journal of Electrical and Computer Engineering (IJECE) Vol 8, No 2: April 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (700.763 KB) | DOI: 10.11591/ijece.v8i2.pp699-710

Abstract

This paper proposed a new algorithm for fault location and classification using wavelet based on Clarke?s transformation to obtain the fault current. This novel method of fault current approach is studied by comparing the use of the glide path of the fault voltage. The current alpha and beta (Current Mode) were used to transform the signal using discrete wavelet transform (DWT). The fault location was determined by using the Clarke?s transformation, and then turned into a wavelet, which was very precise and thorough. The most accurate was the mother wavelet Db4 which had the fastest time and smallest error detection when compared with the other wavelet mothers. In this study, the Clarke?s transformation is also compared with the Karenbauer?s, which has produced results with similar error percentage. The simulation results using PSCAD / EMTDC software showed that the proposed algorithm could distinguish internal and external faults to get the current signal in the transformation of a signal fault.
Netload-Constrained Unit Commitment Considering Increasing Renewable Energy Penetration Levels: Impact of Generation Schedules and Operational Cost Abujarad, Saleh Y.; Mustafa, M. W.; Jamian, J. J.; Abdilahi, Abdirahman M.; Zareen, N.
International Journal of Applied Power Engineering (IJAPE) Vol 7, No 1: April 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijape.v7.i1.pp86-96

Abstract

In the context of low carbon power systems, the penetration levels of Renewable Energy Sources (RES) are expected to increase dramatically. In this regard, this paper investigates the maximum RES penetration level constrained by net load while considering an inflexible Unit Commitment (UC) model. To solve the UC problem, an enhanced priority list (EPL) based method is developed. In the proposed method, the plants were activated sequentially based on the operational price. The system constraint violations were repeatedly corrected until all system constraints (such as net load and spinning reserves) were satisfied. The proposed EPL method was efficient to achieve a near optimal solution under high shares of RES. Furthermore, the research work investigates three different scenarios representing penetration levels of 10% solar-only, 14.5% wind-only and 27.5% mixture of both solar and wind. The impact of each penetration level on the system scheduling and operational cost were analyzed in detail. The analysis presented shows that a potential operational cost savings of 21.6 $/MW, 20 $/MW and 11.1 $/MW is feasible under each of the represented scenarios, respectively.
Minimizing harmonic distortion impact cause by CS using meta heuristic technique Nasir, S. N. Syed; Jamian, J. J.; Mustafa, M. W.
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 17, No 4: August 2019
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (719.45 KB) | DOI: 10.12928/telkomnika.v17i4.12768

Abstract

Non-linear load in the distribution system has caused negative impact to its power quality especially on harmonic distortion. Charging Station (CS) is a non-linear load that widely promoted with the aim to support the continuous usage of Electric Vehicle (EV). This research is focusing on optimal placement and sizing of multiple passive filter to mitigate harmonic distortion due to CS usage at distribution system. There are 6 units of CS which being placed in low voltage buses which indirectly will inject harmonic to the system during charging. Power system harmonic flow, passive filter, CS, battery and the analysis will be model in MATLAB. Multi-objective function which are weight summation approach (WSA) and Pareto Front are used to assist meta heuristic technique which is Modified Lightning Search Algorithm (MLSA) to identify optimum location and sizing of passive filter based on improvement on propose five parameters. From the result, the optimal placements and sizing of passive filter able to reduce the maximum Total Harmonic Distortion (THD) for voltage, current and apparent losses respectively. Therefore, the propose method is suitable to reduce harmonic distortion as well as apparent losses at distribution system with present of CS.