Articles

Found 10 Documents
Search

MODEL PENDEKATAN ALAT UJI KEPADATAN RINGAN UNTUK TANAH DI LABORATORIUM Muda, Anwar
INFO-TEKNIK Vol 17, No 1 (2016): INFOTEKNIK Vol. 17 No. 1 2016
Publisher : Engineering Department, Lambung Mangkurat University

Show Abstract | Original Source | Check in Google Scholar

Abstract

The study is motivated, that during compaction test light to ground in the laboratory with standard equipment ISO 1742: 2008. However, this equipment has not been done as a benchmark or model approaches that have the same standards with ISO 1742: 2008 with a margin of error of ≤ 5%. This study aims to determine whether the test equipment density of light to the ground in a laboratory with a model can be used as a means of testing the density of light to the ground in a laboratory with the same standards as ISO 1742: 2008 with a margin of error of ≤ 5% and give the same assessment of the performance heap.The research method with a step that is preparing the soil samples are clay Palangkaraya and 2 pieces of light density test equipment is ISO 1742: 2008 and the model. Then, the next step is to test the density of the two pieces of the tool.The results showed the maximum dry weight of 1,51 g / cm3 and the optimum water content and soil 25,74% including silt-loam with poor performance forecasts pile up good or clay with a pile of bad performance forecast to moderate. While the maximum density of clay based Model for 5, 10, and 15 collisions per layer and for 20 and 25 collisions per layer as much as 2 layers, obtained by bulk density maximum dry and optimum moisture content with a margin of error of <5% of the ISO 1742: 2008, but do not have the same ratings with ISO 1742: 2008 on the performance of the pile, so that the model has not been qualified as light density test equipment to the ground in a laboratory. For 30 collisions per layer as much as 2 layers, has a bulk density maximum dry and optimum moisture content with a margin of error of <5% of the ISO 1742: 2008 and similar assessments to ISO 1742: 2008 on the performance of the pile, then the model qualifies as test equipment light density to the ground in a laboratory and have the same standards SNI1742: 2008.
Kuat Tekan Bebas Tanah Lempung Bukit Rawi Distabilisasi Pasir dan Semen Muda, Anwar
Anterior Jurnal Vol 15 No 1 (2015): Anterior Jurnal
Publisher : ​Institute for Researches and Community Services Universitas Muhammadiyah Palangkaraya

Show Abstract | Original Source | Check in Google Scholar | Full PDF (167.451 KB)

Abstract

Bukit Rawi clay soil properties only have a value of UCS at 0:41 kg/cm2 so it does not meet the technical requirements Lapis Foundation Under Highway. To that end, will be improved with the addition of sand and cement and is expected to meet the technical requirements highway pavement. The aim of this study was to determine how much the addition of sand and cement on clay soil stabilization Bukit Rawi for pavement highway. The results showed that after the addition of 12% sand with cement 2%, the value of UCS rose to 0:49 kg/cm2 of initial conditions 0:41 kg/cm2. Then, the addition of 4% cement, UCS value also increased by 4:44 kg/cm2. At addition of cement amounted to 6%, the value of UCS has increased to 5:29 kg/cm2 and the addition of cement amounted to 8%, the value of UCS rose to 7:33 kg/cm2 and the addition of cement 10%, the value of UCS increased to 9:06 kg/cm2. So that, with the addition of sand by 12% and 8% of cement optimum technically qualified foundation layer under the highway because of the value of UCS result 7:33 kg/cm2> 7:33 kg/cm2.
MODEL PENDEKATAN ALAT UJI KEPADATAN RINGAN UNTUK TANAH DI LABORATORIUM (PENELITIAN LANJUTAN I) Muda, Anwar
Anterior Jurnal Vol 16 No 2 (2017): Anterior Jurnal
Publisher : ​Institute for Researches and Community Services Universitas Muhammadiyah Palangkaraya

Show Abstract | Original Source | Check in Google Scholar | Full PDF (226.108 KB)

Abstract

The study, entitled "the application of the Model as a means of Testing the density of light to the ground in the lab (Advanced Studies 1)". Backed by research from previous research, entitled "the application of the Model as a means of Testing the density of light for the soil in the laboratory", in previous studies of soil clays used example is the land of clays from the village of Baringan, the city of Palangkaraya. While soil samples in this study used is the land of the village of Palopat Sub-district of Padang Sidempuan PK, Southeast, or rather in the STA 500 Padang Sidempuan 4 heading Mandailing Natal. This study aimed to compare the CBR and UCS clay stabilized sand and cement for the pavement. The research aims to conduct an analysis of the maximum density of soil clays based on Models by as much as 33 collisions per layer as much as 2 layers obtained the maximum dry weight (γd max) and optimum moisture content (w opt) and SNI 1742:2008. If the level of the margin of error is obtained and has 5% < assessment of performance against the same heap, then the Model can be used as a means of testing the density of light to the ground in a lab that has the same standard with SNI 1742:2008.
Analisis Kuat Tekan Bebas Tanah Lempung Distabilisasi Pasir dan Semen Muda, Anwar
Anterior Jurnal Vol 15 No 2 (2016): Anterior Jurnal
Publisher : ​Institute for Researches and Community Services Universitas Muhammadiyah Palangkaraya

Show Abstract | Original Source | Check in Google Scholar | Full PDF (570.235 KB)

Abstract

The purpose of this study was to determine how much additional sand and cement on clay soil stabilization Bukit Rawi to the pavement. The results showed that after the addition of 16% sand with cement 2% the value of UCS rose to 1.63 kg/cm2 of initial conditions 0.41 kg/cm2. Then, the addition of cement 4% of the value of UCS also increased by 6.53 kg/cm2. On the addition of cement amounted to 6% the value of UCS will rise until 7.51 kg/cm2 and the addition of cement amounted to 8% the value increased to 12.08 UCS kg/cm2, and the addition of cement 10% the value increased to 13.06 UCS kg/cm2. Thus, with the addition of 16% sand and cement optimum 10% qualified technical foundation layer under the highway because of the value of UCS result 13.06 kg/cm2 > UCS 6 kg/cm2.
Perbandingan Cbr dan Ucs Tanah Lempung Distabilisasi Pasir dan Semen Muda, Anwar
Anterior Jurnal Vol 16 No 1 (2016): Anterior Jurnal
Publisher : ​Institute for Researches and Community Services Universitas Muhammadiyah Palangkaraya

Show Abstract | Original Source | Check in Google Scholar | Full PDF (278.472 KB)

Abstract

California Bearing Ratio (CBR) is the ratio between load penetration of a substance against a standard material with the depth and penetration of the same speed. While Unconfined Compression Strength (UCS) is the amount of axial load per unit area at the time of the test specimen to collapse or when the axial strain reaches 20%. This study aimed to compare the CBR and UCS clay stabilized sand and cement for the pavement. The results showed that the CBR value increases, the value rises with increasing UCS cement mix. Then when the stabilization of clay with a mixture of 12% sand and 10% cement values obtained UCS at 9.06 kg/cm2 and CBR of 66% thus, stabilization of clay Bukit Rawi qualify for base down the highway because of the value of UCS 9.06 kg/cm2 > UCS 6 kg/cm2 and CBR of 66% > 20%. UCS and CBR rise in value is due to that the addition of semen into adhesive media when it reacts with water. Media adhesive is then solidified and formed a hard mass so it would hold weight.
APLIKASI MODEL SEBAGAI ALAT UJI KEPADATAN RINGAN UNTUK TANAH DI LABORATORIUM Muda, Anwar
Jurnal PROTEKSI (Proyeksi Teknik Sipil) Vol 2, No 1: Edisi Januari 2016
Publisher : Jurusan Teknik Sipil Universitas Palangka Raya

Show Abstract | Original Source | Check in Google Scholar | Full PDF (8.573 KB)

Abstract

Penelitian ini berjudul ―Aplikasi Model Sebagai Alat Uji Kepadatan Ringan Untuk Tanah di Laboratorium‖. Penelitian dilatarbelakangi dari penelitian awal yang berjudul ―Model Pendekatan Alat Uji Kepadatan Ringan Untuk Tanah di Laboratorium‖, di mana dalam penelitian awal dilatarbelakangi, bahwa selama ini pengujian pemadatan ringan untuk tanah di laboratorium dengan peralatan standar SNI 1742:2008. Namun peralatan ini belum pernah dilakukan sebagai pembanding atau model pendekatan yang memiliki standar yang sama dengan SNI 1742:2008 dengan margin error ≤ 5%.   Hasil penelitian menunjukkan, bahwa kepadatan maksimum tanah lempung berdasarkan SNI 1742:2008 didapatkan berat isi kering maksimum (γdmaks) 1.51 gr/cm3 dan kadar air optimum (w22.78%. Tanah ini termasuk jenis lanau-lempung dengan perkiraan kinerja timbunan buruk sampai bagus atau lempung dengan perkiraan kinerja timbunan buruk sampai sedang.  Kemudian, kepadatan maksimum tanah lempung berdasarkan Model saat 33 tumbukan per lapis sebanyak 2 lapis didapatkan berat isi kering maksimum (γdoptimum (woptmaks) 1,51 gr/cm) 23,61%. Tanah ini termasuk jenis lanau-lempung dengan perkiraan kinerja timbunan buruk sampai bagus atau lempung dengan perkiraan kinerja timbunan buruk sampai sedang. Dari analisis ini didapatkan, bahwa kepadatan maksimum tanah lempung berdasarkan Model terdapat tingkat keyakinan 100,00% ≥ 95% dan margin error 0,00% ≤ 5% terhadap berat isi kering maksimum (γd(woptmaks3) dan 96,48% ≥ 95% dan margin error 3,52% ≤ 5% terhadap kadar air optimum ). Pemadatan berdasarkan Model saat 33 tumbukan per lapis sebanyak 2 lapis memiliki tingkat keyakinan ≥ 95% dan memiliki penilaian yang sama dengan SNI 1742:2008 terhadap kinerja timbunan, sehingga aplikasi Model memenuhi syarat sebagai alat uji kepadatan ringan untuk tanah di laboratorium yang memiliki standar yang sama dengan SNI 1742:2008. Model ini perlu disosialisasikan atau seminar-seminar-seminar di kalangan dosen, mahasiswa, instansi pemerintah, instansi swasta dan kalangan profesi sebagai bahan masukan dan koreksi terhadap alat ini. Model ini belum dapat dijadikan sebagai alat uji kepadatan ringan untuk tanah di laboratorium jika belum mendapatkan rekomendasi para ahli atau pakar terhadap alat ini. Kata kunci: aplikasi, model, kepadatan ringan, tanah
Kuat Tekan Bebas Tanah Lempung Distabilisasi Pasir dan Semen untuk Perkerasan Jalan Raya Muda, Anwar
Media Ilmiah Teknik Sipil Vol 5 No 2 (2017): Media Ilmiah Teknik Sipil
Publisher : ​Institute for Researches and Community Services Universitas Muhammadiyah Palangkaraya

Show Abstract | Original Source | Check in Google Scholar | Full PDF (165.192 KB)

Abstract

This study aims to determine the compressive strength of clay and sand stabilized clay soil for pavement. The results showed that the sand stabilization was 12% with 2% cement, the UCS value rose to 0.49 kg / cm2 from the initial condition 0.41 kg / cm2. Then, the addition of cement 4%, the UCS value also increased by 4.44 kg / cm2. On the addition of cement by 6%, the UCS value increased to 5.29 kg / cm2 and the addition of cement by 8%, the UCS value rose to 7.33 kg / cm2 and the addition of cement 10%, the UCS value increased to 9.06 kg / cm2. So, with the addition of sand by 12% and optimum cement 8%, it meets the technical requirements of the lower foundation layer of the road because the UCS value is 7.33 kg / cm2> 6 kg / cm2.
Analisis Mengenai Dampak Lingkungan Paket Pelebaran Jalan RTA Milono Palangkaraya Muda, Anwar
Media Ilmiah Teknik Lingkungan Vol 1 No 1 (2016): Media Ilmiah Teknik Lingkungan
Publisher : ​Institute for Researches and Community Services Universitas Muhammadiyah Palangkaraya

Show Abstract | Original Source | Check in Google Scholar | Full PDF (222.027 KB)

Abstract

Setiap kegiatan pembangunan yang dilaksanakan pasti menimbulkan dampak terhadap lingkungan baik dampak positif maupun dampak negatif. Untuk itu perlu diperhatikan bagaimana melaksanakan pembangunan untuk mendapatkan hasil dan manfaat yang maksimum dengan dampak negatif terhadap lingkungan yang minimum. Penelitian ini bertujuan untuk mengetahui bagian-bagian kajian AMDAL dan permasalahan AMDAL pada Paket Pelebaran Jalan RTA Milono Palangka Raya serta cara penanggulangannya. Hasil penelitian menunjukkan, bahwa kegiatan yang dikaji dari aspek kelayakan lingkungan disebut berwawasan lingkungan. Untuk mencapai hal tersebut diperlukan adanya Analisis Mengenai Dampak Lingkungan. Analisis Mengenai Dampak Lingkungan adalah salah satu instrumen yang sifatnya formal dan wajib bagi kegiatan-kegiatan yang kemungkinan akan menimbulkan dampak besar dari penting terhadap lingkungan hidup. Berdasarkan hasil penelitian ini, maka disarankan untuk pencegahan terjadinya kebisingan, agar mengikuti aturan yang ada seperti peredam suara. Kemudian membuat aturan atau sanksi dalam menjalankan AMDAL sehingga diharapkan dapat meminimalisir dampak lingkungan.
Studi Perencanaan Sistem Pengolahan Limbah RSUD Dr. Doris Sylvanus Palangka Raya Heryanto, Yudha; Muda, Anwar; Bestari, Akhmad; Hermawan, Iwan
Media Ilmiah Teknik Lingkungan Vol 1 No 1 (2016): Media Ilmiah Teknik Lingkungan
Publisher : ​Institute for Researches and Community Services Universitas Muhammadiyah Palangkaraya

Show Abstract | Original Source | Check in Google Scholar | Full PDF (276.545 KB)

Abstract

Perencanaan system instalasi air limbah menggunakan metode mathematical equations model for completely mixed activated sludge dengan analitis data terhadap hasil perencanaan meliputi kriteria pembebanan untuk merencanakan pengolahan limbah dan produksi lumpur serta kebutuhan oksigen, sedangkan bak sedimentasi didasarkan konsep pengendapan ideal dengan pengendapan dari partikel mandiri (discrate pertikel) pada bak klorinasi prinsipnya sama dengan proses pengolahan air minum, hanya saja adanya kandungan padatan tersuspensi dan terlarut sehingga dibutuhkan klorin dengan dosis tergantung derajat pembunuhan bakteri yang diinginkan. Hasil penelitian menunjukkan, bahwa hasil dimensi rancangan unit pengolahan air limbah RSUD dr. Doris Sylvanus memberikan suatu data yang menggambarkan kemampuan instalasi pengolahan air limbah (IPAL) yakni untuk bak penampungan (B=1.5m, L=3m, d=3m), bak aerasi (B=1m, L=2m, d=2m). Bak sedimentasi (B1=2m, L1=2m, d1=1.6m), (B2=0.356m, L2=0.35m, d2=2.529m), dan bak klorinasi (B=2m, L=1m, d=1.6m). Dengan dimensi tersebut dapat mengolah air limbah sebesar 150 m3/hari. Sedangkan besarnya produksi lumpur pada bak aerasi 0.899 kh/hari, massa padatan total pada bak sedimentasi 2.4 kg dan dosis klorin maksimum yang diperlukan sebesar 1.2 mg/hari
Analisis Daya Dukung Tanah Fondasi Dangkal Berdasarkan Data Laboratorium Muda, Anwar
INTEKNA informasi teknik dan niaga Vol 16 No 1 (2016)
Publisher : P3M Politeknik Negeri Banjarmasin

Show Abstract | Original Source | Check in Google Scholar | Full PDF (342.506 KB)

Abstract

Penelitian berjudul ?Analisis Daya Dukung Tanah Fondasi Dangkal Berdasarkan Data Laboratorium?. Penelitian dilatarbelakangi, bahwa selama ini belum pernah dilakukan penelitian di Desa Baringin, kota Palangkaraya dengan mendapatkan nilai kohesi (c) dan sudut geser dalam (?).????????? Penelitian ini bertujuan (1) Untuk menentukan nilai kohesi (c) dan sudut geser dalam (?) tanah Desa Baringin di laboratorium . (2). Untuk menentukan nilai daya dukung tanah pondasi dangkal metode Terzaghi dan Meyerhof serta perbandingan daya dukung tanah kedua metode tersebut.????????? Metode penelitian dengan beberapa tahapan yaitu Tahap persiapan. Tahap ini untuk menyiapkan peralatan hand boring. Tahap pelaksanaan. Tahap ini adalah untuk melakukan hand boring 1 (satu) titik di Desa Baringin, Kota Palangkaraya dan benda uji dibawa ke laboratorium untuk pengujian direct shear C. Tahap akhir. Tahap ini adalah setelah pengujian tanah dengan direct shear kemudian menentukan nilai kohesi (c) dan sudut geser dalam (?) tanah. Dengan nilai kohesi (c)? dan sudut geser dalam (?)? tanah sebagai dasar perhitungan daya dukung tanah pondasi dangkal.Hasil penelitian menunjukkan, bahwa daya dukung tanah ultimit fondasi dangkal metode Meyerhof makin bertambah juga seiring bertambahnya lebar fondasi. Pada lebar fondasi 50 cm diperoleh daya dukung ultimit sebesar 111.35 ton/m2. Kemudian pada lebar fondasi 100 cm, maka daya dukung tanah ultimit makin bertambah hingga 1114.97 ton/m2. Sedangkan pada lebar fondasi 150 cm, daya dukung tanah ultimit makin bertambah lagi sebesar 118.59 ton/m2 dan lebar fondasi 200 cm, maka daya dukung tanah ultimit fondasi dangkal paling tertinggi sebesar 122.22 ton/m2. Daya dukung tanah ultimit fondasi dangkal metode Meyerhof lebih besar dibanding dengan metode Terzaghi. Jika dilihat dari besaran daya dukung tanah ultimit fondasi dangkal, maka daya dukung tanah ultimit metode Meyerhof naik rata-rata sebesar 54.82% dibandingkan dengan metode Terzaghi. Berdasarkan kesimpulan di atas, maka perlu disarankan daya dukung tanah fondasi dangkal berdasarkan data laboartorium perlu dilakukan pembanding dengan data lapangan seperti Dutch Cone Penetrometer. Kemudian, daya dukung tanah fondasi dangkal berdasarkan metode Terzaghi.dan Meyerhof perlu dilakukan pembanding dengan metode Hansen dan Vesic