Articles

Found 3 Documents
Search

Optimasi Kinerja Pompa Sentrifugal Produk Lokal dengan Modifikasi Impeler dan Analisis visualisasi Aliran Siswantoro, Soeadgihardo; Sutrisno, S
Majalah Forum Teknik UGM Vol 27, No 2&3 (2003)
Publisher : Majalah Forum Teknik UGM

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (71.575 KB)

Abstract

A preliminary  efort to  inrprove  an impeller  design for domestic  centrifugal  pump  with  165 mm  outlet  diameter, semi open impeller  has been  initiated  implementing flow visualization method. The  study was focused on  several  impellers  having  different inlet  and  outlet angles, each of  them  has  the  same blade  thickness.A facitity has  been constructed  to  measure  the  performance for those  impellers  at similar speed,  200b  rpm.  The visualization  technique  applied  in  the  study  was  wet paint  method applying  point  on the  surface  of the  impellers  with several  layers  of dffirent  colors  and wetness.Impellers  hwing  optimum  inlet  ond  outlet angles  have been  identified.Keywords :  impeller, flow visualization
PEMANFAATAN PANAS PADA KOMPOR GAS LPG UNTUK PEMBANGKITAN ENERGI LISTRIK MENGGUNAKAN GENERATOR THERMOELEKTRIK Sugiyanto, -; Siswantoro, Soeadgihardo
Jurnal Teknologi Vol 7, No 2 (2014): Desember 2014
Publisher : Jurnal Teknologi

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The government launched the kerosene-to-LPG conversion program in 2007 to help reduce kerosene consumption. This program had increased the number of LPG-stoves in society significantly. LPG-stove has high thermal efficiency, so utilizing some of heat from the stove to direct converts into electrical energy will provide economic value of the stove. The kind of technology that possible to be applied in conversion of heat into electrical energy on the LPG-stove is thermoelectric technology.This research utilized the heat of LPG Stoves RI-511A and RI-300HP using thermoelectric generator TEG127 - 40A and TEG126 - 40A. The heat then converts to electrical energy using technology of Seebeck effect on thermoelectric.The result show that voltage and current generated by TEG126 - 40A is better than TEG127 - 40A. LPG-stove RI-551A using TEG127-40A, voltage and current reached 2.69 V and 0,12 respectively. This result is smaller than using TEG - 40A 126 V that reached 3,59 V and 0,34 A. While the value of the voltage and current generated by TEG127-40A on RI-300HP reached 3,77 V and 0,39 A respectively, but it is still smaller than that using TEG126-40A V that reached 4,17 V and 0,48 A.Keywords: LPG-Stove, Thermoelectric Generator, Energy Conversion, Power Generation.
PEMANFAATAN PANAS PADA KOMPOR GAS LPG UNTUK PEMBANGKITAN ENERGI LISTRIK MENGGUNAKAN GENERATOR THERMOELEKTRIK Sugiyanto, Sugiyanto; Siswantoro, Soeadgihardo
Jurnal Teknologi Vol 7 No 2 (2014): Jurnal Teknologi
Publisher : Jurnal Teknologi, Fakultas Teknologi Industri, Institut Sains & Teknologi AKPRIND Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (321.856 KB)

Abstract

Pemerintah Indonesia meluncurkan program konversi minyak tanah ke LPG pada tahun 2007 menyebabkan jumlah kompor Gas LPG di masyarakat semakin banyak. Kompor LPG memiliki efisiensi thermal yang tinggi sehingga memanfaatkan sebagian panas dari kompor ini akan memberi nilai tambah ekonomis. Salah satu teknlogi yang sangat dimungkinkan untuk diaplikasikan dalam penkonversian panas menjadi energi listrik pada kompor gas LPG tersebut adalah teknologi thermoelektrik. Penelitian ini memanfaatkan panas dari kompor gas LPG RI-511A dan RI-300HP dengan menggunakan thermoelectric generator tipe TEG 127-40A dan TEG 126-40A. Panas ini dikonversi menjadi energi listrik mengunakan efek Seebeck yang ada pada thermoelektrik. Dari pengujian dan analisa data TEG 126-40A lebih baik dalam pembangkitan tegangan dan arus dibandingkan TEG 127-40A. Pengujian dengan kompor RI-551A, nilai tegangan dan arus mencapai 2.69 V, 0.12 A lebih kecil dibandingkan menggunakan TEG 126-40A yang mencapai 3.59 V dan 0.34 A. Sedangkan nilai tegangan dan arus yang dibangkitkan TEG 127-40A pada kompor RI-300HP mencapai 3.77 V dan 0,39 A, masih lebih kecil dibandingkan menggunakan TEG126-40A yang mencapai 4.17 V dan 0.48 A. Kata kunci : , , , .