Ignatius Christiawan
Program D3 Teknik Sipil, Univ. Diponegoro

Published : 4 Documents
Articles

Found 4 Documents
Search

PERKUATAN (STRENGTHENING) STRUKTUR KOLOM DENGAN METODA PENAMBAHAN TULANGAN Christiawan, Ignatius
GEMA TEKNOLOGI Vol 16, No 3 (2011): Periode April 2011 - Oktober 2011
Publisher : GEMA TEKNOLOGI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (71.575 KB)

Abstract

Ignatius Chistiawan, in this paper explain that in the management of buildings, frequent damage to buildings due to the increasing load beyond the load plan. Safety of building users to the dangers of building collapse is the main priority. The addition of load beyond the load on the building plans because of changes in building functions often lead to the collapse of the building. The addition of load beyond the load on the building plans because of changes in building functions often lead to the collapse of buildings. Structural strength evaluation to the condition of existing building is required and when it is necessary to give reinforcement to the plate, beams and columns before adding a new load. additional reinforcement is one way of strengthening the column. Research was focused on performance evaluation of structure on existing condition relate at regulation of the Procedure of Concrete Structure Calculation for the SNI 2847-2002. From some previous research, the basics of analysis and design of flexible and practical calculation examples retrofitting columns with the addition of reinforcement can be concluded that this method is easy and practically implemented and can improve the flexural strength of reinforced concrete columns. Keywords : load addition, evaluation, strength, safety.
PERKUATAN ( STRENGTHENING) STRUKTUR BETON DENGAN FIBER REINFORCED POLYMER (FRP) Christiawan, Ignatius
METANA Volume 6 No. 01 April 2009
Publisher : METANA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstract   In effort fulfill requirement the well building infrastructure, safety of building user such as building avalanche damage as result of earthquake is principal priority. Load addition on building exceeds the planning load as result of the involuntary building function change always generating the building avalanche damage. It was needed evaluate to the strength of building structure at the existing condition and strengthening if it was needed before the structure given the new load. One of the strength procedure is external reinforcement method especially give Fiber Reinforced Polymer (FRP) that it was adhered on the concrete component surface which reinforced by epoxy glue. From several former researches, base analysis and bent planning along with example of the practice calculation of beam strength by FRP can be concluded that the use of FRP in combination with the others strength method is easy and practice for conducted and also capable to increase the strength of concrete beam bent.   Kcywords: load addition, strength, safety
EVALUASI KINERJA DAN PERKUATAN STRUKTUR GEDUNG GUNA ALIH FUNGSI BANGUNAN (Studi Kasus : Perubahan Fungsi Ruang Kelas Menjadi Ruang Perpustakaan Pada Lantai II Gedung G Universitas Semarang) Christiawan, Ignatius; Triwiyono, Andreas; Christady, Hary
Civil Engineering Forum Teknik Sipil Vol 18, No 1 (2008): JANUARI 2008
Publisher : Civil Engineering Forum Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (71.575 KB)

Abstract

To meet the need for good infrastructure of building construction, building new one is not theonly appropriate choice. Efficiency resulted from the functional substitution of existing building to be used with a new function can be a more precise alternative. The existing functional substitutio will result in the change of the building load. Based on the fact, it is necessary to evaluate the performance and the strength of structure at the existing condition to take new load and to calculate the strengthening required. The study is conducted on Building G of Campus III, Semarang University at Jl.Soekarno- Hatta, Semarang. A lecturing space in floor II was proposed to be functionally substituted into library room. It focuses on evaluating performance of structure, the strength of plate, beam, and column, and the bearing of foundation, existing condition based on SNI-2847-2002, earthquake load application based on SNI-1726-2002, and promoting a proposal for strengthening the structure required. The SAP 2000 is used to analyze the structure to gain the required strength value of U (ultimate). BETON 2000 is used to analyze the structure of existing condition to gain the existing strength value of R (resistance). The strengthening of the plate and beam is conducted by adding the Fiber Reinforced Polymer (FRP), while that of column is by adding an external reinforcement The result of the study indicates that the existing fc’ is 17 MPa and the fy is 390 MPa. From evaluation on the performance of structure, it can be known that the performance of servicing limit and that of ultimate limit of the building have really met the requirement of SNI-1726-2002. Based on the result of analysis on the structure of plates in floor 2, plates of A, C, E, and H need the strengthening of flexure ability. Beam in floor 2 : 1 A-E ; 1 E-I ; 2 A-E ; 2 E-I ; 3 C-E and ring beam : 0 A-C ; 0 C-E ; 0 E-G ; 0 G-I ; 3 C-E ; 3 E-I require the strengthening of flexure ability and shear ability. The strengthening of flexure and shear abilities by adding the FRP is found to be able to add the flexure and shearing abilities of plates and beam. The result of analysis on the strengthening of flexure ability by adding reinforcement shows that it can add the flexure ability of column. And form analysis on foundation, it can be known that foundation is able to bear new load so it does not require the strengthening.
EVALUASI KINERJA BANGUNAN AKIBAT PENGARUH GEMPA RENCANA PADA STRUKTUR GEDUNG 3 LANTAI BERDASAR SNI 03-1726-2003 Christiawan, Ignatius
Gema Teknologi Vol 16, No 1 (2010): April 2010 - October 2010
Publisher : Vocational School Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/gt.v16i1.363

Abstract

Ignatius Christiawan, in this paper explain that In effort fulfill requirement the well building infrastructure, safety of building user such as building avalanche damage as result of earthquake is principal priority. Due to user safety to building avalanche as result of earthquake then it was issued the Procedure of Earthquake Endurance Planning SNI 03-1726-2003 that regulates of planning, build or operates a building. Problem emerge at the building which have the old regulation plan, so it was need evaluation based on the new regulation. Evaluation is conducted at the 3 floor laboratory and lecturing building. Research was focused on performance evaluation of structure on existing condition relate at regulation of the Procedure of Concrete Structure Calculation for the SNI 2847-2002, application for earthquake based on SNI-1726-2002. SAP 2000 is used to analyze the pushover to obtain the building ductility value and the reduction factor value (R) from the building. The result of material test was obtained fo? existing 17 Mpa and fy existing 390 Mpa. The result of structure performance evaluation was obtained the service limit performance and the building unlimited performance fulfilling condition SNI ? 1726 ? 2002. Keywords: plan earthquake, evaluation, safety.