POWER-FLOW DEVELOPMENT BASED ON THE MODIFIED BACKWARD-FORWARD FOR VOLTAGE PROFILE IMPROVEMENT OF DISTRIBUTION SYSTEM Suyanto, Suyanto; Rahmadhani, Citra; Penangsang, Ontoseno; Soeprijanto, Adi
International Journal of Electrical and Computer Engineering (IJECE) Vol 6, No 5: October 2016
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (447.169 KB) | DOI: 10.11591/ijece.v6i5.pp2005-2014

Abstract

Unbalanced three-phase radial distribution system has a complex problem in power system. It has many branches and it is sometimes voltage profile?s not stable at every end branches. For improvement of voltage profile, it can be performed by penetrating of a distributed generation models. Information of voltage profile can be gained by study of power flow.  The Modified Backward-Forward is one of the most widely used methods of development of power flow and has been extensively used for voltage profile analysis. In this paper, a study of power flow based on the Modified Backward-Forward method was used to capture the complexities of unbalanced three phase radial distribution system in the 20 kV distribution network in North Surabaya city, East Java, Indonesia within considering distributed generation models. In summary, for the informants in this study, the Modified Backward-Forward method has had quickly convergence and it?s just needed 3 to 5 iteration of power flow simulation which?s compared to other power flow development methods. Distributed Generation models in the modified the modified 34 BUS IEEE system and 20 kV distribution network has gained voltage profile value on limited range. One of the more significant findings to emerge from this development is that the Modified Backward-Forward method has average of error voltage about 0.0017 % to 0.1749%.
Studi Perancangan Sistem Pembumian Gardu Induk 150/20 KV Di Gardu Induk Garuda Sakti Rahmadhani, Citra; Ervianto, Edy
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 4, No 1 (2017): Wisuda Februari Tahun 2017
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The earthing system is a system that should be applied in substations. Its function is to protect both humans and equipments are located around the substation of the danger caused by electrical system fault. The fault that often occurs is short circuit to ground which can cause different voltage gradient between points around the substation. The earthing system is expected to overcome the problems occurred, so that in its design should follow applicable standards. The design of the earthing system at 150/20 kV substation refers to the IEEE Std 80-2000. In this paper, earthing system is designed based on the field datas are extracted from substation Garuda Sakti. Based on design verification, its obtained such as following result i.e. mesh voltage 626.38 V, step voltage 344.46 V, length of the conductor grid 2300 m with 0.55 ? resistance and the conductor achieved in this design able to cover area of 86, 59 mm2. Overall of design was complience to the IEEE Std 80-2000.Keywords - earthing system, substation, touch voltage, step voltage