Alaa, Siti
Universitas Mataram

Published : 2 Documents
Articles

Found 2 Documents
Search

EKSTRAK GETAH PEPAYA (Carica Papaya) DENGAN PENAMBAHAN Cu SEBAGAI DYE SENSITIZER SOLAR CELL (DSSC) Kurniawidi, Dian Wijaya; Alaa, Siti; Rahayu, Susi
Indonesian Physical Review Vol 1, No 1 (2018)
Publisher : Universitas Mataram

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29303/ipr.v1i1.5

Abstract

Indonesia is a biodiversity country. Abundance of biological resources may encourage researchers to optimize its use. As an example papaya trees are utilized as raw material for thin films. Sap of papaya latex is doppinged with Cu. This composition is depositioned on top of FTO by spin coating method. The addition of Cu dopping aims to control the rate of crystallinity of the material. This research will add Cu between 10% and 50% solution. Based on FTIR test results, flavonoid compounds might be obtained with O-H group, some aromatic rings C = C and C = O, aliphatic compounds C-H and -CO. Flavonoid compounds are potentially utilized as dye for DSSC. The thickness of dye produced by doping Cu 10% is approximately (0.5-2) μm. Furthermore, dopping Cu from 20% to 40% can produce thickness around 10-50 nm. Meanwhile, the results of the XRD test show an effective Cu between 10% to 40%.
THE ANALYSIS OF ATTENUATION COEFFICIENT AND ACOUSTIC IMPEDANCE OF CEILING PANEL USING IMPEDANCE CHAMBER METHOD Putramulyo, Satriogi; Wirawan, Rahadi; Alaa, Siti; Qomariyah, Nurul
Indonesian Physical Review Vol 1, No 1 (2018)
Publisher : Universitas Mataram

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29303/ipr.v1i1.7

Abstract

The purposed of this research is to determine the attenuation coefficient and acoustic impedance of ceiling panel like plywood, calsiboard and bamboo woven.  The influence thickness, paint coated, air cavity increment of the attenuation coefficient and acoustic impedance of these ceiling panel are also mesured. The impedance chamber method with range of frequency 100 Hz – 5000 Hz are used here. The result shows that the average of attenuation coefficient for plywood panel, calsiboard panel and bamboo woven panel are 0,37 Npmm-1, 0,62 Npmm-1 and 0,28 Npmm-1 respectively. In addition, the acoustic impedance of these panel is 1,33 x 106 kgm-2s-1, 3,74 x 106 kgm-2s-1 and 1,15 x 106 kgm-2s-1. The attenuation coefficient is decreased with the increasing thickness of the panel and the same trend is founded of the acoustic impedance. Meanwhile, the paint coated can increase attenuation coefficient and acoustic impedance. For the air cavity increment ceiling panel, the attenuation coefficient and acoustic impedance are less than the solid panel.